Cable and transmission distance between devices should follow rules below.
|
Cable Type |
DS-KAD7060EY to Door Station |
DS-KAD7060EY to DS-KAD7061EY |
DS-KAD7061EY to DS-KAD7061EY |
DS-KAD7061EY to Indoor Station |
Indoor Station to Indoor Station |
DS-KAD7060 to DS-KAD7060-S |
Indoor Station to Door Station |
|---|---|---|---|---|---|---|---|
|
UTP 5 0.2 mm2 (Cat.5) AWG24 |
60 m |
60 m |
60 m |
60 m |
100 m |
60 m |
140 m |
|
0.28 mm2 (TP) AWG23 |
60 m |
40 m |
40 m |
40 m |
80 m |
40 m |
160 m |
|
0.5 mm2 (Parallel) AWG20 |
60 m |
60 m |
60 m |
60 m |
100 m |
60 m |
180 m |
|
1 mm2 (Parallel) AWG17 |
60 m |
60 m |
60 m |
60 m |
100 m |
60 m |
260 m |
|
1 mm2 (TP) AWG17 |
60 m |
40 m |
40 m |
40 m |
80 m |
40 m |
260 m |
|
1.5 mm2 (Parallel) AWG15 |
60 m |
40 m |
60 m |
60 m |
100 m |
60 m |
260 m |