System Options

You can set system options such as system fault report, siren delay time, alarm duration, etc.

On the device list page, tap the security control panel and log in to the device (if required) to enter the Area page, and then tap > System Options to enter the System Options page.

Option Management

On the Option Management tab, you can do the following configurations.

Wireless Device Supervision

If enabled, the system will detect the status of all wireless devices.

System Fault Report

If enabled, the system will upload a report automatically when there is a system fault.

Disable Function Key

If enabled, all function keys will be disabled.

Panel Lockup

If enabled, the installer user can still operate the security control panel, while the admin user will not be allowed to operate it.

Siren Delay Time (Perimeter Alarm)

The delay time to trigger the linked siren when a perimeter zone is triggered.

Note:
  • For details about perimeter zone, see the user manual of the security control panel.

  • The valid duration is from 0 s to 600 s.

Alarm Duration

If you have set the perimeter zone, you can set the time duration of the alarm.

Note:

The valid duration is from 1 s to 900 s.

Fault Check

On the Fault Check tab, you can do the following configurations.

Detect Network Camera Disconnection

If enabled, when the linked network camera is disconnected, alarm will be triggered.

Panel Battery Fault Check

If enabled, when battery is disconnected or out of charge, the device will upload an event.

Wired Network Fault Check

If enabled, when the wired network is disconnected or has other faults, alarm will be triggered.

Wi-Fi Fault Check

If enabled, when the Wi-Fi is disconnected or has other faults, alarm will be triggered.

Cellular Network Fault Check

If enabled, when the cellular data network is disconnected or has other faults, alarm will be triggered.

SIM Card Fault Check

If enabled, the alarm will be triggered when the SIM card has faults.

AC Power Down Check Time

An alarm will be triggered if the AC power-down duration exceeds the configured time.

To comply with the EN 50131-3 standards, set the value to 10 s.