You can set a phone number to allow the security control panel to call the phone number or send SMS messages to the phone number when specific alarms (events) are triggered.
If EN50131 Compliant mode is enabled, you should log in to the security control panel first before you can configure the device. For details about enabling EN50131 Compliant mode, see EN50131 Compliant Mode.
> Communication Parameters > Push Notification(s).
| Option | Description |
|---|---|
|
Phone Call |
|
|
SMS |
|
After receiving the phone calls or SMS messages about the alarms (events), you can use your phone to send a control messages to arm/disarm the selected area(s) or clear alarm for the area(s) you selected on the Permission Settings page of the SMS tab.
|
Command |
Operation Type |
Target |
|---|---|---|
|
The number representing the command should be 2 digits. 00: Disarm 01: Away 02: Stay 03: Clear Alarm |
The number representing the operation type should be 1 digit. 1: Area Operation |
The number representing the target area should be no more than 3 digits. 0: All Areas 1: Area 1 ... 4: Area 4 |
For example, the control message which reads 00+1+1 means to disarm area 1; And 01+1+1 means to set the status of area 1 to Away.