You can set the alarm output type and the output delay for the relays of a wireless outputs expander. Alarm output is the node signal or other signal sent from the alarm controller to the peripheral devices when the alarm is triggered.
Make sure you have added wireless outputs expander(s) to the security control panel.
If EN50131 Compliant mode is enabled, you should log in to the security control panel first before you can configure the device. For details about enabling EN50131 Compliant mode, see EN50131 Compliant Mode.
The name of the module and the relays of the expander will be displayed.
If enabled, the relay will be normally closed or open.
The delay time for the relay to become closed. In other words, output delay refers to the duration of the alarm output.
Set the type of the event linked to the relay.
Alarm outputs will be activated when the zones in the selected area(s) alarm.
You can select an event sub-type (e.g, panic alarm) as the event that requires alarm output once it is detected within the zones.
Alarm outputs will be activated when the area(s) you select are armed.
Alarm outputs will be activated when the selected area(s) are disarmed.
Set the switch icon to ON to manually activate alarm outputs of the relay.
Alarm outputs will be activated when the selected zone(s) are triggered or tampered.