You can set the wireless keypad parameters, including device name, buzzer, card/tag swiping, backlight, and security settings, etc.
Make sure you have added wireless keypad to the security control panel.
If EN50131 Compliant mode is enabled, you should log in to the security control panel first before you can configure the device. For details about enabling EN50131 Compliant mode, see EN50131 Compliant Mode.
Set the area linked to the keypad. The linked area can be arm/disarm or clear alarm by the keypad.
Enable the buzzer.
Enable swiping card/tag on the keypad to arm/disarm the linked area or clear alarms.
Enable using keypad to arm/disarm the linked area or clear alarms.
Enable the backlight of the keypad.
If the time during which the keypad loses communication with the security control panel exceeds the configured offline duration, the keypad will be regarded as offline.
When enabled, no linked alarm output (e.g., sound prompt) will be triggered when panic alarms of the keypad is triggered.
Specify the duration that the keypad remains locked if the failed keypad password attempts reach the specified maximum times.
Specify the maximum failed attempts for entering the incorrect keypad password consecutively. If the failure times reaches the specified value, the keypad will remain locked for a specified duration.