Control Areas

You can set arming mode and clear alarms for areas of the security control panel via the Mobile Client. Area, which is an independent control system of a security control panel, allows you to batch arm/disarm all zones in it. If the security control panel has multiple areas, you have multiple independent systems for arming or disarming.

On the device list page, tap the security control panel and then log in to the device to enter the Area page and then control the area. You can swipe to the left or right to switch areas.

Operations for a Single Area

  • Away: When all the people in the detection area leave, turn on the Away mode to arm all zones in the area after the defined dwell time. For example, assume that you have set your apartment as a zone, you can set the zone status to Away when you go to work.

  • Stay: When the people stays inside the detection area, turn on the Stay mode to turn on all the perimeter burglary detection (such as perimeter detector, magnetic contacts, curtain detector in the balcony). At the meantime, the detectors inside the detection area are bypassed (such as PIR detectors). People can move inside the area and alarm will not be triggered.

  • Disarm: In Disarm mode, all the zones in the area will not trigger alarm, no matter the selected events are detected or not.

  • Clear Alarm: Clear all the alarms triggered by the zones of the area.

Operations for All Areas

  • Away: When all the people in the detection area leave, turn on the Away mode to arm all zones in all areas after the defined dwell time.

  • Stay: When the people stays inside the detection area, turn on the Stay mode to turn on all the perimeter burglary detection (such as perimeter detector, magnetic contacts, curtain detector in the balcony) set in all the zones of all areas. At the meantime, the detectors inside the detection area are bypassed (such as PIR detectors). People can move inside the area and alarm will not be triggered.

  • Disarm: In Disarm mode, all the zones of all areas will not trigger alarm, no matter the selected events are detected or not.

  • Clear Alarm: Clear all the alarms triggered by the all the zones of all the areas.