You can set the alarm output type and the output delay for the relays of
a wireless outputs expander. Alarm output is the node signal or other signal sent from the
alarm controller to the peripheral devices when the alarm is triggered.
Make sure you have added wireless outputs expander(s) to the security
control panel.
-
On the device list page, tap the security control panel and then log in to the
device to enter the Area page.
-
Tap Peripheral Device and then tap a wireless outputs
expander on the device list.
The relays of the expander will be displayed.
- Optional:
Set the disconnection duration.
- Offline Duration
-
If the time during which the wireless outputs
expander loses communication with the security control panel
exceeds the configured offline duration, the wireless outputs
expander will be regarded as offline.
Note:
The default offline duration is 1 hour.
-
Configure the relay.
| Option |
Description |
|
Edit Relay Name
|
Tap a relay and then tap the relay name to edit its
name. And then tap to save the changes.
|
|
Select Alarm Output Type
|
Tap a relay and then select an alarm output type.
- Alarm
-
Alarm outputs will be activated when the
zone alarms.
- Arming
-
Alarm outputs will be activated when the area
(system) is armed.
- Disarming
-
Alarm outputs will be activated when the
area is disarmed.
- Manual
-
Set the switch icon to ON in the relay list
to manually activate alarm outputs of the relay.
- Zone
-
Alarm outputs will be activated when the
selected zone is triggered or tampered.
|
|
Set Delay Time for the Relay to Close
|
Tap a relay and then tap Output
Delay to set the delay time for the relay to close.
In other words, output delay refers to the duration of the alarm
output.
|