Edit Door for Current Site

You can edit the basic information, related cameras, picture storage settings, card reader settings, and face recognition terminal settings of a door on the current site.

  1. In the top left corner of Home page, select > Basic Management > Device.
  2. Click Area on the left.
  3. In the left panel, select the added current site from the drop-down site list to show its areas and select one area.
    Note:

    The icon indicates that the site is current site.

  4. Select the Door tab to show the added doors in this area.
  5. Click a door's name in the Name column to enter the door editing page.
  6. Edit the door's basic information.
    Name

    Edit the name for the door.

    Note:

    If you change the name, you can click in the door list page to apply the new name to the device.

    Door Contact

    The door contact's connection mode.

    Exit Button Type

    The exit button connection mode.

    Lock Door when Door Closed

    If it is enabled, the door will be locked once the door magnetic is closed. If there is no door magnetic, the door will be locked after the extended open duration ends.

    Note:

    This function should be supported by the device.

    Open Duration

    The time interval between the door is unlocked and locked again.

    Extended Open Duration

    The time interval between the door is unlocked and locked again for the person whose extended access function is enabled.

    Door Open Timeout Alarm

    After enabled, if the door has been configured with the event or alarm, when the door contact open duration has reached the limit, the event or alarm will be uploaded to the system.

    Duress Code

    If you enter this code on the card reader keypad, the Control Client will receive a duress event. It should be different from the super password and dismiss code.

    Super Password

    If you enter this password on the card reader keypad, you are exempted from all the remaining locked (Credential Failed), anti-passback, and first card authorization restrictions. It should be different from the duress code and dismiss code.

    Dismiss Code

    If you enter this code on the card reader keypad, the buzzer's beeping will be stopped. It should be different from the duress code and supper password.

  7. Link cameras to the door, and you can view its live view, recorded videos, and captured pictures via the Control Client.
    Note:
    • Up to 2 cameras can be linked to one door.

    • You can click or to adjust the priority of cameras.

    • You can switch on Auto Capture to enable automatic capture of the camera.

  8. Optional: Switch on Picture Storage and select a storage location from the drop-down list.
    Note:

    For details, refer to Configure Storage for Uploaded Pictures. If an error occurs during picture storage configuration, appears on the right of the door name.

  9. Optional: On the Card Reader panel, switch on Card Reader 1 or Card Reader 2 and set the card reader related parameters.
    Min. Card Swipe Interval

    After it is enabled, you cannot swipe the same card again within the minimum card swiping interval.

    Reset Entry on Keypad After(s)

    Set the maximum time interval of pressing two keys on the keypad. If timed out, the first entry will be reset.

    Failed Card Attempts Alarm

    After it is enabled, if the door is configured with event or alarm, when the number of excessive failed card swiping attempts has reached the limit, the event or alarm will be uploaded to the system.

    Tampering Detection

    After it is enabled, if the door is configured with device tampered event or alarm, when the device body or panel is taken apart, the alarm will be triggered and sent to the system.

    OK LED Polarity

    Only supported when the device is connected via Wiegand interface. The polarity for OK core wire connection on the card reader mainboard.

    Error LED Polarity

    Only supported when the device is connected via Wiegand interface. The polarity for ERR core wire connection on the card reader mainboard.

    Face 1:N Matching Threshold

    Set the threshold when authenticating via 1:N matching mode. The larger the value, the smaller the false accept rate. The maximum value is 100.

    Face Recognition Interval

    The time interval between continuous face recognition twice when authenticating.

    Face Anti-spoofing

    If it is enabled, the device can recognize the live face. Also, you can check Protect Sensitivity of Face Anti-Proofing, and set the face anti-spoofing security level.

    Face Recognition Application Mode

    Select Indoor or Others according to actual environment.

    Note:

    The parameters displayed vary according to the different models of the access control devices. For details about the parameters, refer to the user manual of the device.

  10. Optional: For a turnstile or an access controller of certain types, switch on Face Recognition Terminal and add face recognition terminals to link with the selected turnstile.
    1. Click Add to enter the Add Face Recognition Terminal page.
    2. Select IP Address, Online Devices, or Device ID as the adding mode, and set the required parameters, which may vary according to different terminals.
    3. Click Add to link the terminal to the turnstile or access controller.
    4. Optional: Click in the Operation column to configure parameters for the terminal. For details, refer to Configure Other Parameters.
  11. Optional: Click Copy To in the upper right corner to apply the current settings of the door to other door(s).
  12. Click Save.