Edit Elevator for Current Site

You can edit basic information, floor information, related cameras, card reader settings of the elevator on current site.

  1. In the top left corner of Home page, select > Basic Management > Device.
  2. Click Area on the left.
  3. In the left panel, select the current site from the drop-down site list to show its areas.
    Note:

    The icon indicates that the site is the current site.

  4. Optional: Select an area.
  5. Select the Elevator tab to show the added elevators in this area.
  6. Click an elevator's name in the Name column to enter the elevator editing page.
  7. Edit the elevator's basic information.
    Name

    Edit the name for the elevator.

    Note:

    If you changes the name, you can click in the elevator list page to apply the new name to the device.

    Open Duration

    The time interval between the elevator door is open and closed again.

    Extended Open Duration

    The time interval between the elevator door is open and closed again for the person whose extended access function is enabled.

    Elevator Door Open Timeout Alarm

    After enabled, if the elevator has configured with event or alarm, when the elevator door open duration has reached the limit, the event or alarm will be uploaded to the system.

    Max. Open Duration

    The time interval between the elevator door is unlocked and locked again if the person has enabled Extended Access function.

    Duress Code

    If you enter this code on the card reader keypad, the Control Client will receive a duress event. It should be different with the super password and dismiss code.

    Super Password

    If you enter this password on the card reader keypad, you are exempted from all the remaining locked (Credential Failed), anti-passback, and first card authorization restrictions. It should be different with the duress code and dismiss code.

    Dismiss Code

    If you enter this code on the card reader keypad, the buzzer's beeping will be stopped. It should be different with the duress code and super password.

  8. In the Floor panel, all the imported floors will be displayed in the list. You can edit the floor's name or reset the imported floor No.
    Edit Floor Name

    You can edit the floor name if needed.

    Note:

    If you changes the name, you can click Apply Floor Name in the elevator list page to apply the new name to the device.

    Reset Imported Floor No.

    You can click Reset Imported Floor No. and enter the range of the floor No. to reset the settings of the floors, such as schedule settings, name, access level settings, etc.

  9. Relate cameras (such as the cameras mounted inside the elevator) to the elevator, and you can view its live view, recorded video, captured pictures via the Control Client.
    Note:
    • Up to two cameras can be related to one elevator.

    • You can select the door and click or to adjust the displaying priority of its auto capture.

    • You can switch on Auto Capture to realize the function of capturing automatically.

  10. In the Card Reader panel, switch on Card Reader 1 or Card Reader 2 and set the card reader related parameters.
    Min. Card Swipe Interval

    After enabled, you cannot swipe the same card again within the minimum card swiping interval.

    Reset Entry on Keypad after

    Set the maximum time interval of pressing two keys on the keypad. If timed out, the first entry will be reset.

    Failed Card Attempts Alarm

    After enabled, if the door has configured with event or alarm, when the number of excessive failed card swiping attempts has reached the limit, the event or alarm will be uploaded to the system.

    Tampering Detection

    After enabled, if the door has configured with device tampered event or alarm, when the device body or panel is taken apart, the alarm will be triggered and sent to the system.

    OK LED Polarity

    Only supported when the device is connected via Wiegand interface. The polarity for OK core wire connection on the card reader mainboard.

    Error LED Polarity

    Only supported when the device is connected via Wiegand interface. The polarity for ERR core wire connection on the card reader mainboard.

    Buzzer Polarity

    Only supported when the device is connected via Wiegand interface. The polarity for buzzer connection on the card reader mainboard.

    Fingerprint Security Level

    Select the fingerprint security level. The higher is the security level, the lower is the face acceptance rate (FAR). The higher is the security level, the higher is the false rejection rate (FRR).

    Note:

    The parameters displayed vary according to the model of the access control device. For details about the parameters, refer to the user manual of the device.

  11. Optional: Click Copy to in the upper right corner to apply the current settings of the elevator to other elevator(s).
  12. Click Save.