Generate Temperature Analysis Report

For thermal cameras, you can generate a report to show the number of exceptions (temperature too high or too low) and maximum/minimum temperature of different thermometry points on different presets.

  1. In the top left corner of the platform, select > Intelligent Analysis > Report > Temperature Analysis.
  2. Select the preset(s) configured on the thermal camera(s) for statistics.
    1. Select a current site or remote site from the drop-down site list to show its thermal cameras.
      Note:

      Only the online thermal cameras will be displayed here.

    2. Select the thermal camera(s) for statistics.
    3. Check the preset(s) configured on the camera.
      Note:

      For configuring the thermometry point with temperature measurement rules, refer to the user manual of the thermal camera.

    The corresponding report of selected preset(s) is displayed.

  3. Set the statistical cycle as Day, Week, Month, Year, or Custom.
    Daily Report

    Daily report shows data on a daily basis. The platform will calculate the temperature data detected in each hour of one day.

    Weekly Report, Monthly Report, Annual Report

    As compared to daily report, weekly report, monthly report, and annual report can be less time-consuming, since they are not to be submitted every day. The platform will calculate the temperature data detected in each day of way week, in each day of one month, and in each month of one year.

    Custom Time Interval

    Users can customize the days in the report to analyze temperature data detected in each day or month of the custom time interval.

  4. Select a pre-defined time period or customize a time period for statistics.
    Note:

    For custom time interval report, you need to set the start time and end time to specify the time period.

  5. Optional: Perform the following operation(s) after generating the temperature report.
    Option Description

    View Temperature Report of Single Preset

    Click the preset name on the report to view the detailed report of the preset.

    View Temperature Report of Single Thermometry Point

    1. Click the preset name on the report to view the detailed report of the preset.

    2. In the Item for Comparison field, select one thermometry point.

    3. In the Item for Comparison field, select the indicator you want to view in the chart.

      High/Low Temperature

      Shows the number of exceptions that the temperature at this thermometry point is higher or lower than the pre-defined temperature.

      Max. Temperature

      Shows the maximum temperature at this thermometry point during the set time period.

      The temperature is displayed in line chart, indicating the trend.

      Min. Temperature

      Shows the minimum temperature at this thermometry point during the set time period.

      The temperature is displayed in line chart, indicating the trend.

  6. Click Add to Dashboard to display the report on the Dashboard.
  7. Optional: Export the report to the local PC.
    1. Click Export.

      The Export panel will display with camera selected and time configured according to the range you defined previously.

    2. Set the format of the exported file as Excel, CSV, or PDF.
    3. Select shorter time period to view more detailed data of each camera.

      For example, if you select Daily Report, you can select By Day or By Hour, or By Minute and it will export 1, 24, or 24×60 records respectively for each thermometry point.

    4. Select the content to export.
      Abnormal Temperature

      Export the number of exceptions on temperature (temperature too high or too low) of each thermometry point.

      Skin-Surface Temperature Status

      Export the maximum temperature and minimum temperature of each thermometry point.

    5. Click Export.