For thermal cameras, you can generate a report to show the number of
exceptions (temperature too high or too low) and maximum/minimum temperature of different
thermometry points on different presets.
-
In the top left corner of the platform,
select .
-
Select
the
preset(s) configured on the thermal camera(s) for
statistics.
-
Select a current site or remote site from the drop-down site list to
show its thermal cameras.
Note:
Only
the
online thermal cameras will be displayed
here.
-
Select
the thermal camera(s) for statistics.
-
Check the preset(s) configured on the camera.
Note:
For configuring the thermometry point with
temperature measurement rules, refer to the user manual of the
thermal camera.
The corresponding report of selected preset(s) is displayed.
-
Set the statistical cycle as Day,
Week, Month,
Year, or Custom.
- Daily Report
-
Daily report shows data on a daily basis. The
platform will calculate the temperature data detected in each
hour of one day.
- Weekly Report, Monthly Report, Annual Report
-
As compared to daily report, weekly report, monthly
report, and annual report can be less time-consuming, since they
are not to be submitted every day. The platform will calculate
the temperature data detected in each day of way week, in each
day of one month, and in each month of one year.
- Custom Time Interval
-
Users can customize the days in the report to analyze
temperature data detected in each day or month of the custom
time interval.
-
Select a pre-defined time period or customize a time period for
statistics.
Note:
For custom time interval report, you need to set the start
time and end time to specify the time period.
- Optional:
Perform the following operation(s) after generating the temperature
report.
| Option |
Description |
|
View Temperature Report of Single Preset
|
Click the preset
name
on the
report
to view
the
detailed report
of the
preset.
|
|
View Temperature Report of Single Thermometry Point
|
-
Click
the preset name on the report to view the detailed report of
the preset.
-
In the Item for
Comparison field, select one thermometry
point.
-
In the Item for
Comparison field, select the indicator you
want to view in the chart.
- High/Low Temperature
-
Shows the number of exceptions that
the temperature at this thermometry point is
higher or lower than the pre-defined temperature.
- Max. Temperature
-
Shows the maximum temperature at this
thermometry point during the set time period.
The temperature is displayed in line
chart, indicating the trend.
- Min. Temperature
-
Shows the minimum temperature at this
thermometry point during the set time period.
The temperature is displayed in line
chart, indicating the trend.
|
-
Click Add to Dashboard to display the report on the
Dashboard.
- Optional:
Export the report to the local PC.
-
Click Export.
The Export panel will display with camera selected and
time configured according to the range you defined previously.
-
Set the format of the exported file as Excel,
CSV,
or PDF.
-
Select shorter time period to view more detailed data of each
camera.
For example, if you select Daily Report, you can select
By Day or By Hour,
or By Minute and it will export 1, 24, or
24×60 records respectively for each thermometry point.
-
Select the content to export.
- Abnormal
Temperature
-
Export the number of exceptions on
temperature (temperature too high or too low) of each
thermometry point.
- Skin-Surface
Temperature Status
-
Export the maximum temperature and minimum
temperature of each thermometry point.
-
Click Export.